Module 2: Pediatric Airway and Breathing
of 55
One provider uses both hands to open the airway with a jaw thrust and maintain a tight mask-to-face seal
- The second provider squeezes the bag and may apply cricoid pressure if appropriate
- Both providers should verify adequate chest expansion
- Misting may be seen on the facemask on exhalation
- End tidal CO2 monitoring can be attached to the circuit to verify effective ventilation
Module 2: Pediatric Airway and Breathing