Module 2: Pediatric Airway and Breathing
       
   of 55
  
  
  
    
  
  
    
            Prepare equipment using Broselow tape:
	- Predicted size of endotracheal tube including one ETT size above and below
 
	- 2 working laryngoscopes (size-appropriate blades)
 
	- Working suction (size-appropriate tips)
 
	- Self-inflating bag connected to high-flow oxygen
 
	- CO2 detector (colorimetric or continuous)
 
	- Eschmann stylet and alternative airway equipment
 
	- Drugs to be used for the procedure and resuscitation drugs 
 
	- EKG, SaO2, BP, NIBP monitoring
 
 
      